Schneider EPP302LCD Dry Panel Static Differential Pressure/air Sensor ModuleSchneider EPP302LCD Dry Panel Static Differential Pressure/air Sensor ModuleSchneider EPP302LCD Dry Panel Static Differential Pressure/air Sensor ModuleSchneider EPP302LCD Dry Panel Static Differential Pressure/air Sensor Module

Schneider Electric EPP302LCD Dry Panel Static Differential Pressure/Air Sensor Module

EP Series Differential Pressure/Air Velocity Transducer, Panel Mounting, 0-1 in. WC / 0-250 Pa, LCD

Overview

This is a Schneider Electric EPP302LCD, an EP Series differential pressure/air velocity transducer built for dry, panel-mounted installation. It measures static differential pressure across a range of switch-selectable spans from 0-0.1" W.C. (0-25 Pa) up to 0-1" W.C. (0-250 Pa), displaying readings on a built-in LCD. Rated IP65 for plant room environments, it's designed for continuous monitoring of duct pressure, filters, fans, and VAV systems in HVAC and building automation applications.

Key Features

  • Multi-range pressure measurement: Field-selectable ranges spanning 0-0.1", 0-0.25", 0-0.5", and 0-1" W.C. (0-25 to 0-250 Pa) to fit different monitoring needs.
  • Built-in LCD display: Compact 17 x 28 mm display for direct, on-panel readout of pressure values.
  • Local LED status signaling: Red/green/blue LED indication for at-a-glance status monitoring.
  • Robust IP65 protection: Sealed housing suited to plant room environments and demanding industrial conditions.
  • Flexible power input: Operates on 12-30 V DC or 24 V AC supply.
  • Low measurement drift: Pressure measurement drift held to less than 2%, supporting long-term reading accuracy.
  • Wide operating temperature range: Rated for continuous operation from -20°C to 60°C.

What's Included

Model Function Qty
EPP302LCD Panel-mount differential pressure/air sensor with LCD 1

Technical Specifications

Pressure measurement ranges: 0-0.1" W.C. (0-25 Pa); 0-0.25" W.C. (0-50 Pa); 0-0.5" W.C. (0-100 Pa); 0-1" W.C. (0-250 Pa).

Pressure measurement drift: Less than 2%.

Supply voltage [Us]: 12-30 V DC or 24 V AC.

Display: LCD, 17 x 28 mm.

Local signaling: Red/green/blue LED.

Fitting: 6 mm (0.24") male fitting.

Protection: IP65.

Ambient operating temperature: -20°C to 60°C.

Standards: EN 61000-6-3, EN 61000-6-1, EN 61326-1, EN 61326-2-3.

Mounting: Panel mounting.

Dimensions: 88 mm (W) x 112 mm (H) x 42 mm (D); probe diameter 7 mm, probe length 188 mm.

Net weight: 0.125 kg.

Compatibility & Applications

Designed for use with air and gas fluids, this sensor is well suited to duct pressure monitoring, filter monitoring, fan monitoring, VAV control, and air velocity monitoring in plant room and building automation environments where reliable, panel-mounted differential pressure sensing is required.